TABLE 1

Comparison of kinetic parameters for DBZ metabolites formed in RLMs and HLMs

The quantity of each metabolite was represented by its area under the curve (AUC) on the chromatogram, because calibration was unnecessary for the purpose of this comparison. Values are means ± S.E. obtained from three independent experiments.

KmVmaxVmax/Km
RLMHLMRLMHLMRLMHLM
μMAUC/min/mg
M141.8 ± 1.324.7 ± 1.3*12.9 ± 0.30.63 ± 0.03**0.308 ± 0.0150.026 ± 0.002**
M247.9 ± 0.425.0 ± 1.3*7.1 ± 0.50.58 ± 0.02**0.149 ± 0.0080.023 ± 0.002**
M342.2 ± 0.319.6 ± 0.5*18.7 ± 1.91.89 ± 0.08**0.443 ± 0.0420.096 ± 0.003**
M434.2 ± 0.724.1 ± 0.8*41.9 ± 2.60.95 ± 0.06**1.227 ± 0.1000.040 ± 0.001**
M531.5 ± 1.623.2 ± 0.5*7.6 ± 0.50.97 ± 0.05**0.242 ± 0.0030.042 ± 0.002**
  • * p < 0.05.

  • ** p < 0.01 versus the RLM values.