Abstract
Quantification of metabolites by mass spectrometry in the absence of authentic reference standards or without a radiolabel is often called "semiquantitative," which acknowledges that mass spectrometric responses are not truly quantitative. For many researchers, it is tempting to pursue this practice of semiquantification in early drug discovery and even preclinical development, when radiolabeled absorption, distribution, metabolism, and excretion studies are being deferred to later stages of drug development. The caveats of quantifying metabolites based on parent drug response are explored in this investigation. A set of 71 clinically relevant drugs/metabolites encompassing common biotransformation pathways was subjected to flow injection analysis coupled with electrospray ionization (ESI) mass spectrometry. The results revealed a large variation in ESI response even for structurally similar parent drug/metabolite pairs. The ESI response of each metabolite was normalized to that of the parent drug to generate an ESI relative response factor. Overall, relative response factors ranged from 0.014 (>70-fold lower response than parent) to 8.6 (8.6-fold higher response than parent). Various two-dimensional molecular descriptors were calculated that describe physicochemical, topological, and structural properties for each drug/metabolite. The molecular descriptors, along with the ESI response factors, were used in univariate analyses as well as a principal components analysis to ascertain which molecular descriptors best account for the observed discrepancies in drug/metabolite ESI response. This investigation has shown that the practice of using parent drug response to quantify metabolites should be used with caution.
Introduction
Quantitative assessments are at the heart of pharmaceutical drug discovery and development. They usually involve the quantification of parent drug exposure, because this informs absorption, distribution, metabolism, and excretion properties, as well as efficacy and toxicity. Quantification of drug or drug-related material is thus vital to assessments of pharmacokinetics, efficacy, toxicokinetics, and toxicity. In addition to qualitative assessments of metabolic pathways, often called "metabolite identification," and quantification of parent disappearance, termed as "metabolic stability," the potential benefits of metabolite quantification cannot be ignored. For example, metabolite quantification in drug discovery and development can help identify gaps and better define the pharmacological and toxicological properties of a drug, e.g., primary pathway/s of metabolic clearance, pharmacologically active metabolites, reactive/toxic metabolites, metabolite-mediated drug-drug interactions, etc. The routine application of metabolite quantification in drug discovery and early development is hindered by the absence of reference standards and/or radioisotope labeled compound, both of which are typically available much later in the development lifecycle. Recent advancements in the analytical specificity and sensitivity of liquid chromatography mass spectrometry (LC/MS) approaches has also lessened the focus and need for radiolabeled absorption, distribution, metabolism, and excretion studies early in drug development (Obach et al., 2012).
Various analytical approaches, e.g., equimolar detection based on nitrogen or sulfur chemiluminescence (Laks et al., 2004), charged aerosol, evaporative light scattering detection (Magnusson et al., 2015), inductively coupled plasma mass spectrometry (Zhang et al., 2016), as well as UV detection and nuclear magnetic resonance spectroscopy (Vishwanathan et al., 2009), have been explored for quantification of analytes in the absence of reference standards. Nonetheless, LC/MS is the predominant technique for quantification of drugs in biologic matrices (Lee and Kerns, 1999), making an approach based on LC/MS highly desirable. For this reason, the practice of using LC/MS response of the parent drug to calibrate the response of metabolites appears attractive as a surrogate to address the need for quantitative data, although it is fraught with liabilities and pitfalls. Electrospray ionization is sensitive to analyte structure and resulting molecular properties, e.g., surface activity, nonpolar surface area, etc., which can significantly affect relative signal intensity between two seemingly similar molecules (Cech and Enke, 2001). This can have profound consequences when using parent drug response to quantify a metabolite, because large errors may result that can lead project teams astray. Unfortunately, these liabilities are often forgotten by scientists when pressured by the demands of project teams and tight timelines and are therefore brushed aside by qualifying data as "semiquantitative."
This manuscript explores the relationship between parent drug and metabolite structures linked by specific biotransformation pathways for a large and diverse number of compounds. The results revealed a large variation in ESI response even for structurally similar parent drug/metabolite pairs, analogous to that observed by Jones’ group (Dahal et al., 2011), for a small set of compounds. Simple univariate analyses as well as principal components analysis (PCA) with molecular descriptors were used to investigate potential causes of the observed response variations. The results of this investigation confirm for a wide range of compounds and their biotransformations that the practice of using parent drug response to calibrate the response of metabolites is problematic at best, can frequently lead to incorrect conclusions and should be avoided in its entirety.
Materials and Methods
Chemicals and Reagents.
Synthetic standards of 26 pharmaceutical drugs and 45 metabolites were obtained from Toronto Research Chemicals (Toronto, Canada) or Sigma-Aldrich (St. Louis, MO) and are listed in Supplemental Table 1. Dimethyl sulfoxide (DMSO, 99.7% purity) and formic acid (98% purity) were obtained from Sigma-Aldrich. Acetonitrile and water were both of LC/MS grade and were purchased from J. T. Baker (Center Valley, PA).
LC/MS Analysis of Drugs and Metabolites.
LC/MS was performed using an Agilent 6530 quadrupole-time-of-flight (Qq-ToF) mass spectrometer with an Agilent Jet Stream electrospray ionization source. The Qq-ToF was coupled to an Agilent 1290 Infinity LC (Agilent, Santa Clara, CA). The Qq-ToF was calibrated daily in the 2-GHz extended linear dynamic range mode. Solutions of all drugs and metabolites were prepared at 1 mM in dimethyl sulfoxide. These solutions were serially diluted using 50/50 acetonitrile/water (v/v) to generate individual standard curves ranging from 1 to 1000 nM. All standards were analyzed in triplicate using the LC/MS system, but in flow injection analysis mode, i.e., a chromatographic column was not used. This experimental setup was used to ensure all compounds entered the Qq-ToF dissolved in a consistent mobile phase composition. Flow injection analysis was performed using a mobile phase composition of 50/50 acetonitrile/water at 0.3 ml/min flow rate and a temperature of 30°C. All data were acquired in positive ion, full scan mode from m/z 100 to 1500 using a capillary voltage of 4500 V, drying gas temperature of 350°C, and a fragmentor voltage of 175 V. All compounds were detected as protonated molecule ions, i.e., [M+H]+, using high-resolution accurate mass spectrometry on the Qq-ToF with the parameters listed above. This experimental setup enabled a consistent detection platform for all compounds, and eliminated the need for determining compound specific parameters, which is required for multiple reaction monitoring on a triple quadrupole mass spectrometer, e.g., collision energy and gas setting.
Data Analysis.
Data acquisition and postacquisition peak integration and linear calibration of acquired data were performed using Agilent Mass Hunter software (v. B.05.01, Build 5.01.5125.3). Microsoft Excel (Microsoft, Redmond, WA) was used to perform any further postprocessing data analysis. Chromatograms of individual drugs/metabolites were extracted from the total ion chromatogram using an extraction window of 5 ppm. Integrated peaks of all standards were used to prepare linear standard curves with 1/x2 weighing. Points were excluded from the standard curve if their back-calculated concentrations were not within +/− 30% of their nominal concentration. This was done to ensure that all subsequent data analysis was performed within the linear range of response for all drugs and metabolites. It was determined that all drugs/metabolites in this study were within their linear range of response at a concentration of 100 nM. The integrated peak area of metabolites was normalized to the integrated peak area of its corresponding parent drug to generate an ESI RF, as shown in eq. 1. These RFs were used to facilitate visualization of the data, as well as for subsequent data analysis by principal components analysis.
(1)Calculation of Molecular Descriptors and Principal Components Analysis.
All compounds were coded as SMILES strings as input for the calculations. Physicochemical descriptors were calculated using VolSurf+ (Molecular Discovery Ltd., Borehamwood, UK) (Cruciani et al., 2000) and included 105 parameters describing physicochemical, topological, and structural properties, including molecular size, shape, hydrophilicity, and hydrophobicity. The physicochemical descriptors for each metabolite were normalized to the equivalent set of parameters calculated for the corresponding parent drug to derive a differential physicochemical "fingerprint" for each metabolite. Differential logD7.4 was calculated as logD7.4 metabolite minus logD7.4 parent. The data matrix including metabolite-to-parent RF and metabolite-to-parent physicochemical descriptor ratios were imported into Volsurf+ for the purposes of principal components analysis. The data were then mean centered prior to PCA. With mean-centering, the average value of each variable is calculated and then subtracted from the data, making it possible to directly compare variables. This also negates a single variable from dominating the analysis. PCA methods involve the calculation of linear combinations of the original descriptors, the principal component’s (PC’s), such that each PC is orthogonal to all others with the first PC (PC1) containing the largest amount of variance with subsequent PCs containing progressively less variance. Thus, a plot of PC1 versus PC2 provides the most efficient two-dimensional representation of the information contained in the data set.
Results and Discussion
The measured relative RF of metabolite-to-parent drug for 45 drug metabolites representing five categories of biotransformation (conjugation, carbon oxidation, heteroatom oxidation, dealkylation, and hydrolysis) is shown in Fig. 1. A relative RF of 1 indicates equal response of the metabolite compared with its parent drug. Overall, in the data set, RF values ranged from 0.014 for resorufin glururonide (>70-fold lower response than parent) to 8.6 (8.6-fold higher response than parent) for hydroxymethoxy diclofenac. Within specific categories, RF ranged between 0.014 and 2.7 for conjugations, 0.04 and 8.6 for carbon oxidations, 0.05 and 1.8 for dealkylations, and 0.24 and 4.4 for heteroatom oxidations. Twenty-one drug metabolites had a RF within twofold of unity, which is an error margin far greater than the 15% value based on bioanalytical regulatory guidance (Booth and Kadavil, 2013), or even the 30% value, which is commonly used in drug discovery. RF values from only 10 and 13 drug metabolites fell within the 15% and 30% bioanalytical limits, respectively. This means that more than half of the total number of data points were outside the limits represented by the twofold margin, and more than 75% were outside the limits represented by 15% error margin. Closer examination of these data points reveals that with the exception of desethyl resorufin ethyl ether, dealkylation seemed to be the most likely biotransformation that preserved the equivalence of response from parent drug. Although it is observed that unmasking a polar group, which is the endpoint of dealkylation metabolic reactions, keeps the RF value within twofold, it should be noted that most of the metabolites in this study were a result of N-dealkylations, resulting in formation of corresponding primary and secondary amines, and not O-dealkylations that lead to primary or secondary alcohols or phenols, for example. Thus, the evidence presented for dealkylation reactions in this investigation may inherently be biased by formation of metabolites that ionize readily under the present conditions. Also, the corresponding aldehydes, which are the other products formed in the dealkylation reactions, were not a part of this investigation because of the unstable chemical nature of aliphatic aldehydes. Heteroatom oxidation, e.g., N- and S-oxides, sulfides, and sulfoxides, with the exception of the sulfone metabolite of fenbendazole, was the next most likely biotransformation that keeps the RF value within twofold. Perusal of the data for the other 24 data points whose RF was not within a factor of 2 of unity, revealed 42% with RFs <2 and 11% with RFs >2, with conjugative metabolism, e.g., glucuronidation and sulfation, resulting in the most variable RFs as a group. This observation makes intuitive sense, because conjugative metabolism represents a significant increase in size and hydrophilicity of a molecule. Somewhat surprisingly, oxidation of carbon atoms also resulted in significant changes in RF, although this biotransformation is not as impactful on structure and molecular properties as conjugative metabolism. For instance, just under half of the drugs undergoing oxidation at a carbon atom had RFs close to unity. Hydrolytic cleavage metabolites, e.g., nafamostat, resulted in RFs close to unity; however, this is not conclusive given the small sample size.
Figure 1 offers conclusive evidence that the practice of using LC/MS response of a parent drug to calibrate the response of its metabolite(s) is most likely to lead to significant errors and, accordingly, incorrect conclusions concerning the importance of a particular biotransformation pathway on the overall metabolic clearance and drug interaction potential of a pharmaceutical drug. This is exemplified with the case of resorufin ethyl ether, where the response for resorufin glucuronide and the ethyl ether parent is >1300-fold different. Although changes in RF have been categorized according to biotransformation, Fig. 1 does not show which molecular (or physicochemical) property may be most responsible for driving the observed changes in RF. In this analysis, logD7.4 was determined to be the single most important physicochemical property for describing the change in RF. This is consistent with the observation that compound polarity correlates with ESI response (Cech and Enke, 2001) and with results from a different study that found logD7.4 to be a key parameter in predicting relative RF of amino acids/metabolites through multivariate calibration (Chalcraft and Britz-McKibbin, 2009). Figure 2 shows the change in RF as a function of the differential logD7.4 between metabolite and parent drug categorized by the type of biotransformation. The goodness of fit (R2) is low at 0.24 but it does illustrate a trend that the more hydrophilic a metabolite is relative to parent, the lower the relative RF is likely to be. Furthermore, in this data set, logD7.4 unit differences of less than 1 unit lower led to relative RF values of 0.1 or lower. And conjugative metabolites incorporating significant changes in logD7.4 (4-5 units lower) can lead to relative RF values of 0.01–0.1. The trend with logD7.4 was apparent for each category of biotransformation, with the exception of carbon oxidation, where there was no trend at all between logD7.4 and relative RF. This may suggest other physicochemical determinants are important for these types of metabolites, because this is a relatively small change in chemical structure (introduction of 1 hydrogen bond donor) but led to the widest range in RF values (after conjugative reactions). To this point, the structure-activity relationship was taken a step further by analyzing a broader set of calculated physicochemical descriptors together with RF values. Figure 3 is the PCA scores plot showing the clustering of biotransformations based on relative RF and relative difference in physicochemical properties. It shows that different types of biotransformations tend to cluster together, based on their RF values and physicochemical properties. This suggests that a computational modeling approach may provide a means to predict the likely RF based on structural descriptors that could be used in the early stages of drug discovery, before availability of authentic metabolic standards or radiolabeled material.
Very limited information, if any, can be obtained from downstream applications of semiquantification approaches. Calculation of metabolite formation kinetics based on relative peak areas in the absence of a reference standard is also incorrect. Kinetic rates such as maximal velocity of metabolic reaction cannot be truly ascertained without an authentic reference standard of a metabolite (Argikar and Nagar, 2014). Michaelis-Menten kinetics describe metabolic processes at steady state and are represented by Km, the substrate concentration at half-maximal velocity (concentration at Vmax/2, with units of concentration) and Vmax, maximal rate (with units of concentration per unit time, sometimes normalized to concentration of enzyme used in the experiment). To obtain Vmax, reaction velocity (v) has been plotted versus substrate concentration [S] (Seibert and Tracy, 2014). A true Vmax cannot be obtained by plotting relative peak areas of metabolites to parent, thus rendering the subsequent kinetic analysis fundamentally incorrect. In this case, the analysis is further compromised by the assumption that the linearity of metabolite MS response with concentration is equivalent to the parent drug. Similarly, in vivo pharmacokinetics cannot be accurately assessed either with the so-called "semiquantification" results. Elimination half-life is typically independent of a true concentration and may be calculated by plotting mass spectrometric response over the terminal phase, with the assumption of linearity within a detector’s dynamic range. However, primary pharmacokinetic parameters such as area under the concentration-time curve, clearance, and volume of distribution at steady state obtained for metabolites in the absence of an authentic reference standard or a radiometric detector would be considered meaningless.
This investigation has shown that the practice of using parent drug response to quantify metabolites should be used with caution. There are many examples of this practice in the literature, but these will not be cited in this manuscript. The RF values obtained in the present investigation ranged from 0.014 to 8.6. The acceptable error margin of 15% based on regulatory guidance for bioanalysis in drug development should yield a theoretical RF range of 0.85 to 1.15. It is incomprehensible how such a large discrepancy as seen in this study or even literature examples of RF values of twofold can be considered acceptable. In the context of the MIST guidance (US Food and Drug Administration, 2016), where disproportionate metabolites are considered as 10% or greater of total drug-related exposure at steady state, such a RF range makes the use of mass spectrometric responses far from favorable. From a drug discovery perspective, the current technology limits the use of mass spectrometric responses, because it is impossible to predict RF as a vector for unknown metabolites, i.e., it is not possible to calculate the directionality or magnitude of the change in RF even with in silico approaches. It is evident from our investigation that large discrepancies in parent drug/metabolite RF can result from seemingly small biotransformations, i.e., errors in metabolite quantification can far exceed twofold (or greater) based on our results. The nature of these discrepancies makes it difficult to predict when a mass spectrometric response for metabolite is overestimated, equal, or underestimated, thus casting doubt on when semiquantification can or cannot be reliably used. ESI response of drugs and their metabolites are thought to be a function of chemical structure along with molecular properties, as well as the constituents and pH of the mobile phase, flow rates, parameters of the ESI source, protonation/deprotonation, resonance and inductive effects in drugs, and their metabolites, which affect chemical reactivity for ionization, etc. Until an exact understanding of how one or more of these variables affects ionization individually or multifactorially, predictive algorithms for semiquantification of metabolites will be limited at best. Although it is beyond the scope of the present investigation to demonstrate a predictive model, future work will involve increasing the data set for higher statistical significance, modeling different response parameters, e.g., raw peak area and work toward building a greater understanding of the structure-activity relationship and potentially predictive models.
Acknowledgments
The authors acknowledge Jonathan Kenney for help in preparing solutions for this study.
Authorship Contributions
Participated in research design: Hatsis, Argikar.
Conducted experiments: Hatsis, Waters, Argikar.
Contributed new reagents or analytic tools: Hatsis, Waters.
Performed data analysis: Hatsis, Waters, Argikar.
Wrote or contributed to the writing of the manuscript: Hatsis, Waters, Argikar.
Footnotes
- Received January 26, 2017.
- Accepted March 1, 2017.
↵This article has supplemental material available at dmd.aspetjournals.org.
Abbreviations
- ESI-MS
- electrospray ionization mass spectrometry
- LC/MS
- liquid chromatography mass spectrometry
- PC
- principal component
- PCA
- principal component analysis
- Qq-ToF
- quadrupole-time-of-flight
- RF
- response factor
- Copyright © 2017 by The American Society for Pharmacology and Experimental Therapeutics