Skip to main content
Advertisement

Main menu

  • Home
  • Articles
    • Current Issue
    • Fast Forward
    • Latest Articles
    • Special Sections
    • Archive
  • Information
    • Instructions to Authors
    • Submit a Manuscript
    • FAQs
    • For Subscribers
    • Terms & Conditions of Use
    • Permissions
  • Editorial Board
  • Alerts
    • Alerts
    • RSS Feeds
  • Virtual Issues
  • Feedback
  • Submit
  • Other Publications
    • Drug Metabolism and Disposition
    • Journal of Pharmacology and Experimental Therapeutics
    • Molecular Pharmacology
    • Pharmacological Reviews
    • Pharmacology Research & Perspectives
    • ASPET

User menu

  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Drug Metabolism & Disposition
  • Other Publications
    • Drug Metabolism and Disposition
    • Journal of Pharmacology and Experimental Therapeutics
    • Molecular Pharmacology
    • Pharmacological Reviews
    • Pharmacology Research & Perspectives
    • ASPET
  • My alerts
  • Log in
  • Log out
  • My Cart
Drug Metabolism & Disposition

Advanced Search

  • Home
  • Articles
    • Current Issue
    • Fast Forward
    • Latest Articles
    • Special Sections
    • Archive
  • Information
    • Instructions to Authors
    • Submit a Manuscript
    • FAQs
    • For Subscribers
    • Terms & Conditions of Use
    • Permissions
  • Editorial Board
  • Alerts
    • Alerts
    • RSS Feeds
  • Virtual Issues
  • Feedback
  • Submit
  • Visit dmd on Facebook
  • Follow dmd on Twitter
  • Follow ASPET on LinkedIn
Rapid CommunicationSpecial Section on Transporters in Drug Disposition and Pharmacokinetic Prediction—Short Communication

Comparison of Proteomic Quantification Approaches for Hepatic Drug Transporters: Multiplexed Global Quantitation Correlates with Targeted Proteomic Quantitation

Anna Vildhede, Chuong Nguyen, Brian K. Erickson, Ryan C. Kunz, Richard Jones, Emi Kimoto, Francis Bourbonais, A. David Rodrigues and Manthena V.S. Varma
Drug Metabolism and Disposition May 2018, 46 (5) 692-696; DOI: https://doi.org/10.1124/dmd.117.079285
Anna Vildhede
Pharmacokinetics, Dynamics and Metabolism (A.V., E.K., A.D.R., M.V.S.V.) and Discovery Sciences (C.N., F.B.), Medicine Design, Pfizer Worldwide R&D, Groton, Connecticut; IQ Proteomics, Cambridge, Massachusetts (B.K.E., R.C.K.); and MS Bioworks, Ann Arbor, Michigan (R.J.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chuong Nguyen
Pharmacokinetics, Dynamics and Metabolism (A.V., E.K., A.D.R., M.V.S.V.) and Discovery Sciences (C.N., F.B.), Medicine Design, Pfizer Worldwide R&D, Groton, Connecticut; IQ Proteomics, Cambridge, Massachusetts (B.K.E., R.C.K.); and MS Bioworks, Ann Arbor, Michigan (R.J.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Brian K. Erickson
Pharmacokinetics, Dynamics and Metabolism (A.V., E.K., A.D.R., M.V.S.V.) and Discovery Sciences (C.N., F.B.), Medicine Design, Pfizer Worldwide R&D, Groton, Connecticut; IQ Proteomics, Cambridge, Massachusetts (B.K.E., R.C.K.); and MS Bioworks, Ann Arbor, Michigan (R.J.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ryan C. Kunz
Pharmacokinetics, Dynamics and Metabolism (A.V., E.K., A.D.R., M.V.S.V.) and Discovery Sciences (C.N., F.B.), Medicine Design, Pfizer Worldwide R&D, Groton, Connecticut; IQ Proteomics, Cambridge, Massachusetts (B.K.E., R.C.K.); and MS Bioworks, Ann Arbor, Michigan (R.J.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Richard Jones
Pharmacokinetics, Dynamics and Metabolism (A.V., E.K., A.D.R., M.V.S.V.) and Discovery Sciences (C.N., F.B.), Medicine Design, Pfizer Worldwide R&D, Groton, Connecticut; IQ Proteomics, Cambridge, Massachusetts (B.K.E., R.C.K.); and MS Bioworks, Ann Arbor, Michigan (R.J.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Emi Kimoto
Pharmacokinetics, Dynamics and Metabolism (A.V., E.K., A.D.R., M.V.S.V.) and Discovery Sciences (C.N., F.B.), Medicine Design, Pfizer Worldwide R&D, Groton, Connecticut; IQ Proteomics, Cambridge, Massachusetts (B.K.E., R.C.K.); and MS Bioworks, Ann Arbor, Michigan (R.J.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Francis Bourbonais
Pharmacokinetics, Dynamics and Metabolism (A.V., E.K., A.D.R., M.V.S.V.) and Discovery Sciences (C.N., F.B.), Medicine Design, Pfizer Worldwide R&D, Groton, Connecticut; IQ Proteomics, Cambridge, Massachusetts (B.K.E., R.C.K.); and MS Bioworks, Ann Arbor, Michigan (R.J.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A. David Rodrigues
Pharmacokinetics, Dynamics and Metabolism (A.V., E.K., A.D.R., M.V.S.V.) and Discovery Sciences (C.N., F.B.), Medicine Design, Pfizer Worldwide R&D, Groton, Connecticut; IQ Proteomics, Cambridge, Massachusetts (B.K.E., R.C.K.); and MS Bioworks, Ann Arbor, Michigan (R.J.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Manthena V.S. Varma
Pharmacokinetics, Dynamics and Metabolism (A.V., E.K., A.D.R., M.V.S.V.) and Discovery Sciences (C.N., F.B.), Medicine Design, Pfizer Worldwide R&D, Groton, Connecticut; IQ Proteomics, Cambridge, Massachusetts (B.K.E., R.C.K.); and MS Bioworks, Ann Arbor, Michigan (R.J.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • eLetters
  • PDF + SI
  • PDF
Loading

Abstract

Targeted protein quantification using liquid chromatography–tandem mass spectrometry with stable isotope-labeled standards is recognized as the gold standard of practice for protein quantification. Such assays, however, can only cover a limited number of proteins, and developing targeted methods for larger numbers of proteins requires substantial investment. Alternatively, large-scale global proteomic experiments along with computational methods such as the “total protein approach” (TPA) have the potential to provide extensive protein quantification. In this study, we compared the TPA-based quantitation of seven major hepatic uptake transporters in four human liver tissue samples using global proteomic data obtained from two multiplexed tandem mass tag experiments (performed in two independent laboratories) to the quantitative data from targeted proteomic assays. The TPA-based quantitation of these hepatic transporters [sodium-taurocholate cotransporting polypeptide (NTCP/SLC10A1), organic anion transporter 2 (OAT2/SLC22A7), OAT7/SLC22A9, organic anion-transporting polypeptide 1B1 (OATP1B1/SLCO1B1), OATP1B3/SLCO1B3, OATP2B1/SLCO2B1, and organic cation transporter (OCT1/SLC22A1)] showed good-to-excellent correlations (Pearson r = 0.74–1.00) to the targeted data. In addition, the values were similar to those measured by targeted proteomics with 71% and 86% of the data sets falling within 3-fold of the targeted data. A comparison of the TPA-based quantifications of enzyme abundances to available literature data showed that the majority of the enzyme quantifications fell within the reference data intervals. In conclusion, these results demonstrate the capability of multiplexed global proteomic experiments to detect differences in protein expression between samples and provide reasonable estimations of protein expression levels.

Introduction

Quantification of transport proteins is an important component to facilitate in vitro–in vivo extrapolation (IVIVE), and thus the mechanistic modeling of drug disposition (Prasad and Unadkat, 2014; Vildhede et al., 2016). Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is generally considered the method of choice for the identification and quantification of proteins (Han et al., 2008). Typically, the proteins are enzymatically digested into peptides, which are then separated and analyzed by LC-MS/MS (Walther and Mann, 2010). Peptide concentrations are thus measured as surrogates of protein abundance.

There are essentially two main strategies for mass spectrometry-based proteomic analysis. In targeted proteomics, a predefined set of peptide ions, uniquely identifying proteins of interest, and one or more of their fragment ions are selected and monitored for accurate quantification of each peptide using an external calibration curve. Because of the reproducibility and high selectivity and sensitivity of the method, targeted proteomics is considered the gold standard for protein quantification (Peterson et al., 2012). It does, however, suffer from limited throughput, as there are practical restrictions to the number of peptides that can be targeted in a single run with reliable quantification (Lange et al., 2008).

In contrast to targeted proteomics, global or shotgun proteomics aims to identify as many proteins as possible in a sample. This is achieved by operating the mass spectrometer in data-dependent acquisition mode (Zhang et al., 2013). Precursor ions are detected in a survey scan followed by fragmentation of a subset, typically selected by highest signal abundances. From the fragment spectra, the identities of the peptides can be determined by sequence database searching, and the peptides are then assigned to proteins. To convert the spectral intensities to protein concentrations, a computational method termed the “total protein approach” (TPA) was recently proposed and validated (Wiśniewski et al., 2012). The method does not require standards and is applicable to any large-scale proteomic data set. It thus offers an efficient way to quantify all identified proteins in a sample. This approach is, however, expected to be less reproducible than targeted proteomic quantifications owing to the stochastic sampling of precursor ions for fragmentation, thus affecting run-to-run reproducibility (Tabb et al., 2010).

To reduce the impact of run-to-run variability when comparing protein abundances between different samples, multiplexing at the sample level is possible. For example, tandem mass tags (TMT) can be used to introduce isotope-based differences to the samples via chemical labeling (Thompson et al., 2003). This approach was initially reported to suffer from interference, resulting in ratio distortions, a problem that was solved by an additional fragmentation step, i.e., triple-stage mass spectrometry (MS3) (Ting et al., 2011).

In this study, we aimed to evaluate the quantitative ability of the total protein approach using MS3 spectral data obtained from two independently performed TMT experiments. To assess quantification accuracy, calculated protein levels were compared with the abundances determined by targeted proteomics for a set of hepatic uptake transporters that are of relevance in drug disposition.

Materials and Methods

Human Liver Tissue.

Normal human liver tissue samples from four different donors were obtained from the Pfizer Tissue Bank (Groton, CT). Collection of these samples was conducted in a manner compliant with Pfizer policies, including ethical approval.

Targeted Proteomic Quantification of Hepatic Uptake Transporters.

Surrogate peptide levels for sodium taurocholate cotransporting polypeptide (NTCP), organic anion transporter 2 (OAT2), OAT7, organic anion transporting polypeptide 1B1 (OATP1B1), OATP1B3, OATP2B1, and organic cation transporter 1 (OCT1) were measured by modification of previously published quantitative targeted proteomic methods (Kimoto et al., 2012; Qiu et al., 2013), and with guidance on the choice of proteotypic surrogate peptides from other publications (Sakamoto et al., 2011; Groer et al., 2013). Details of the targeted proteomic methodology are provided in Supplemental Methods. In brief, membrane proteins were extracted from the human liver samples and digested with trypsin (Supplemental Fig. 1). The resulting mixture of peptides was spiked with known quantities of stable isotope-labeled peptides as internal standards. Peptides were then separated and analyzed by LC-MS/MS in multiple-reaction monitoring mode. Chromatographic peak areas of target fragment ions in relation to their respective stable isotope-labeled internal standard were used to calculate peptide concentrations (as surrogate of protein levels) with an external calibration curve prepared in digested human serum albumin matrix.

Multiplexed Global Proteomic Analysis of Liver Tissue Samples and Quantification of Protein Abundances.

Liver tissue samples from the same donors included in the targeted proteomic quantification were analyzed by multiplexed global proteomics in two independent laboratories: MS Bioworks (Ann Arbor, MI) and IQ Proteomics (Cambridge, MA) using their in-house protocols. For the global proteomic experiments, proteins (both soluble and membrane-bound) were extracted by homogenization and lysis of the liver tissue samples (Supplemental Fig. 1). Proteins were digested with trypsin (laboratory 1) or Lys-C and trypsin in tandem (laboratory 2), and the resulting peptide samples were labeled with isobaric TMT reagents in technical duplicates. After labeling, samples were mixed and peptides were subjected to high pH reverse-phase fractionation, followed by LC-MS/MS/MS analysis on Orbitrap Fusion Lumos instruments (Thermo Fisher Scientific, Waltham, MA). MS3 spectral intensities of the reporter ions, formed upon fragmentation, were used to calculate protein abundances under the assumption that the MS signal for a given protein in relation to the summed MS signals for all identified proteins reflects its partial abundance in the sample (Wiśniewski, 2017). A more detailed description of the TMT experiments is provided in Supplementary Methods.

Statistical Analysis.

Correlations of protein abundance measurements across laboratories were assessed by Pearson’s correlation coefficients (r). Protein abundance values calculated from the TMT data were compared with those determined in the targeted proteomic experiment by Dunnett’s multiple comparison tests and by calculating fold errors.

Results and Discussion

To evaluate the quantitative merits of the multiplexed global proteomics approach, and to justify its utility in quantitative translation needed for system pharmacokinetics, we compared transporter protein levels in human liver samples acquired from TMT data to the abundances determined by validated targeted proteomic methods. For this comparison, TMT data obtained from two independent laboratories with different sample processing protocols were used.

Surrogate peptide abundance levels of the major hepatic uptake transporters involved in drug disposition, namely NTCP, OAT2, OAT7, OATP1B1, OATP1B3, OATP2B1, and OCT1, were measured in four human liver tissue samples. All these transporters were detected in the liver tissue samples analyzed with measured abundances within the ranges observed in previous studies (Kimoto et al., 2012; Qiu et al., 2013; Peng et al., 2015; Wang et al., 2015). For the four samples included in this study, NTCP showed ∼6-fold intersubject variability, whereas the variability of the other transporters was ∼2- to 3-fold (Table 1).

View this table:
  • View inline
  • View popup
TABLE 1

Comparison of the average protein abundance and range (interindividual variability) in protein abundance for four human liver tissue samples measured with two different proteomic methodologies, targeted proteomics, and multiplexed global proteomics using tandem mass tag (TMT) reagents

LC-MS/MS/MS run time was 24 hours for laboratory 1 and 48 hours for laboratory 2.

Human liver tissue samples from the same donors included in the targeted proteomic quantification were analyzed in two separate TMT experiments, performed in two independent laboratories. The samples were analyzed in technical duplicates. Very high correlations (Pearson r > 0.99) in MS3 intensities for the replicate measurements were observed, indicating a good precision of the TMT method. More than 5000 proteins were identified in each TMT experiment, demonstrating a sufficient depth of analysis for the TPA-based quantification of protein abundances (Wiśniewski, 2017). Among the identified proteins were the seven uptake transporters of interest (Table 1). For laboratory 1, however, NTCP was not detected in MS3 mode and, thus, MS2 data were used instead. The lack of NTCP detection in MS3 mode was likely a result of the shorter MS acquisition time for this TMT experiment compared with the other one (24-hour compared with 36-hour). Moreover, because of the stochastic element of precursor ion fragmentation in data-dependent acquisition mode, proteins of interest are not always identified in complex samples (Tabb et al., 2010). This is especially true for less abundant proteins, such as NTCP, when the selection criterion for fragmentation is chosen on the basis of peptides with the highest signal abundances. To increase the probability of identifying the proteins of interest, enrichment through subcellular fractionation is possible, although isolated fractions are reported to be associated with lower yields than expected (Wiśniewski et al., 2016; Wegler et al., 2017). Another option is to perform data-independent acquisition on the proteome-scale using a recently introduced technique known as SWATH-MS (Gillet et al., 2012).

The calculated protein abundances from the TMT experiments were compared with the targeted protein quantifications (Fig. 1). For this comparison, a membrane-to-total protein ratio of 0.233 (in-house data, n = 42) was used to convert the measured abundances to the same unit. The TMT data showed good-to-excellent correlations (Pearson r = 0.74–1.00) to the targeted proteomic data (Fig. 1, A–G). We attribute this cross-laboratory agreement to the confident identification of peptides in the TMT experiments and to the thorough analytical validation of the targeted proteomic assays to avoid false positive identifications caused by matrix interference (Balogh et al., 2012; Qiu et al., 2013; Carr et al., 2014). The good correlations observed in our study are in stark contrast to the predominantly poor correlations of transporter and enzyme protein levels across laboratories reported elsewhere (Achour et al., 2017; Wegler et al., 2017). In such cases, correlations with activity measurements are necessary to determine which proteomic methodology results in expression data that align with functional activity. Unfortunately, it is not possible to measure transport activities in frozen liver tissue samples.

Fig. 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1.

Comparison of protein quantifications by multiplexed global proteomics (y-axis) and targeted proteomics (x-axis). Cross-laboratory correlation analysis of protein abundance measurements for NTCP (A), OAT2 (B), OAT7 (C), OCT1 (D), OATP1B1 (E), OATP1B3 (F), and OATP2B1 (G). Data are presented as arithmetic means with standard deviations (n = 3 for the targeted proteomic data, n = 2 for the TMT data). r = Pearson correlation coefficient. Quantitative agreement of protein abundances calculated from the multiplexed global proteomic data to those measured by targeted proteomics (H). The solid line represents the line of unity, dotted lines represent 2-fold deviations, dashed lines represent 3-fold deviations, and the dot-dash lines represent 5-fold deviations. LC-MS/MS/MS run time was 24 hours for laboratory 1 and 48 hours for laboratory 2. NTCP was not detected in MS3 mode for laboratory 1, and hence, MS2 data were used instead.

In addition to the excellent correlations of measured protein concentrations across methods observed in our study, the transporter abundances calculated from the TMT data resulted in values comparable to those measured by targeted proteomics with absolute fold errors within 3-fold for 71% and 86% of the data set for the two TMT experiments, respectively (Fig. 1H). Furthermore, the range (interindividual variability) in protein expression was very similar across methods (Table 1), suggesting that the multiplexed global proteomic approach can be used to reliably detect differences in protein levels across samples.

The better quantitative agreement for laboratory 2 suggests that longer run-times are required for more reliable quantifications. This observation is in agreement with the finding that higher quantification accuracy is obtained when proteins are identified by a larger number of peptides (Wiśniewski and Rakus, 2014). Differences in the sample processing protocols, including the use of sequential enzymatic digestion with Lys-C and trypsin (laboratory 2) compared with digestion with trypsin alone (laboratory 1), can also add to the quantitative differences observed, when the former is expected to reduce missed cleavages and enhance protein sequence coverage (Guo et al., 2014).

To further assess the accuracy of the TPA-based quantifications, we compared the abundances of cytochrome P450 (CYP) and UDP-glucuronosyltransferase (UGT) drug-metabolizing enzymes with literature data (Fig. 2). Most of the enzyme quantifications fell within the ranges reported in literature. In addition, there was a good quantitative agreement between the two different TMT experiments with an average absolute fold error of 2.1 for the CYP enzymes and 3.5 for the UGT enzymes, respectively.

Fig. 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 2.

Comparison of cytochrome P450 (A) and UGT (B) enzyme abundances, quantified by multiplexed global proteomics, to the range (white bars) and weighed mean (solid gray line) from two recent meta-analyses (Achour et al., 2014a,b).

In summary, our results suggest that multiplexed global proteomic experiments with sufficient proteome coverage can provide reasonable estimates of protein concentrations, as demonstrated with a set of major hepatic uptake transporters, as well as drug-metabolizing enzymes. More importantly, such experiments accurately capture differences in protein levels across samples and may thus be used to compare in vitro and in vivo expression for IVIVE exercises. The global proteomic approach also supports the simultaneous quantification of thousands of other proteins, thus providing a much larger dataset than that obtained by targeted proteomics. Such data can, for example, be useful when studying the age-, gender-, ethnicity-, disease-, and drug-dependent expression of transporters and other drug disposition-related proteins in various tissues or when assessing the appropriateness of an in vitro model compared with the in vivo counterpart. Our study is the first to present evidence suggesting that MS3 intensities from TMT experiments can be applied to TPA-based protein quantifications. Additional validation employing the multiplexed global proteomic approach presented herein can further strengthen its application in quantitative proteomics.

Authorship Contributions

Participated in research design: Vildhede, Nguyen, Erickson, Kunz, Jones, Kimoto, Bourbonais, Rodrigues, Varma.

Conducted experiments: Vildhede, Kunz, Jones.

Performed data analysis: Vildhede, Nguyen.

Wrote or contributed to the writing of the manuscript: Vildhede, Nguyen, Erickson, Kunz, Jones, Kimoto, Bourbonais, Rodrigues, Varma.

Footnotes

    • Received November 2, 2017.
    • Accepted February 8, 2018.
  • https://doi.org/10.1124/dmd.117.079285.

  • ↵Embedded ImageThis article has supplemental material available at dmd.aspetjournals.org.

Abbreviations

CYP
cytochrome P450
LC
liquid chromatography
MS/MS (MS2)
tandem mass spectrometry; MS/MS/MS (MS3); triple-stage mass spectrometry
NTCP
sodium taurocholate cotransporting polypeptide
OAT2
organic anion transporter 2
OAT7
organic anion transporter 7
OATP1B1
organic anion-transporting polypeptide 1B1
OATP1B3
organic anion-transporting polypeptide 1B3
OATP2B1
organic anion-transporting polypeptide 2B1
OCT1
organic cation transporter 1
TMT
tandem mass tag
TPA
total protein approach
UGT
UDP-glucuronosyltransferase
  • Copyright © 2018 by The American Society for Pharmacology and Experimental Therapeutics

References

  1. ↵
    1. Achour B,
    2. Barber J, and
    3. Rostami-Hodjegan A
    (2014a) Expression of hepatic drug-metabolizing cytochrome p450 enzymes and their intercorrelations: a meta-analysis. Drug Metab Dispos 42:1349–1356.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    1. Achour B,
    2. Dantonio A,
    3. Niosi M,
    4. Novak JJ,
    5. Fallon JK,
    6. Barber J,
    7. Smith PC,
    8. Rostami-Hodjegan A, and
    9. Goosen TC
    (2017) Quantitative characterization of major hepatic UDP-glucuronosyltransferase enzymes in human liver microsomes: comparison of two proteomic methods and correlation with catalytic activity. Drug Metab Dispos 45:1102–1112.
    OpenUrlAbstract/FREE Full Text
  3. ↵
    1. Achour B,
    2. Rostami-Hodjegan A, and
    3. Barber J
    (2014b) Protein expression of various hepatic uridine 5′-diphosphate glucuronosyltransferase (UGT) enzymes and their inter-correlations: a meta-analysis. Biopharm Drug Dispos 35:353–361.
    OpenUrlCrossRefPubMed
  4. ↵
    1. Balogh LM,
    2. Kimoto E,
    3. Chupka J,
    4. Zhang H, and
    5. Lai Y
    (2012) Membrane protein quantification by peptide-based mass spectrometry approaches: studies on the organic anion-transporting polypeptide family. J Proteomics Bioinform 6:229–236.
    OpenUrl
  5. ↵
    1. Carr SA,
    2. Abbatiello SE,
    3. Ackermann BL,
    4. Borchers C,
    5. Domon B,
    6. Deutsch EW,
    7. Grant RP,
    8. Hoofnagle AN,
    9. Hüttenhain R,
    10. Koomen JM, et al.
    (2014) Targeted peptide measurements in biology and medicine: best practices for mass spectrometry-based assay development using a fit-for-purpose approach. Mol Cell Proteomics 13:907–917.
    OpenUrlAbstract/FREE Full Text
  6. ↵
    1. Gillet LC,
    2. Navarro P,
    3. Tate S,
    4. Rost H,
    5. Selevsek N,
    6. Reiter L,
    7. Bonner R, and
    8. Aebersold R
    (2012). Targeted data extraction of the MS/MS spectra generated by data-independent acquisition: a new concept for consistent and accurate proteome analysis. Mol Cell Proteomics 11(6):O111 016717.
    OpenUrlCrossRef
  7. ↵
    1. Gröer C,
    2. Brück S,
    3. Lai Y,
    4. Paulick A,
    5. Busemann A,
    6. Heidecke CD,
    7. Siegmund W, and
    8. Oswald S
    (2013) LC-MS/MS-based quantification of clinically relevant intestinal uptake and efflux transporter proteins. J Pharm Biomed Anal 85:253–261.
    OpenUrlCrossRefPubMed
  8. ↵
    1. Guo X,
    2. Trudgian DC,
    3. Lemoff A,
    4. Yadavalli S, and
    5. Mirzaei H
    (2014) Confetti: a multiprotease map of the HeLa proteome for comprehensive proteomics. Mol Cell Proteomics 13:1573–1584.
    OpenUrlAbstract/FREE Full Text
  9. ↵
    1. Han X,
    2. Aslanian A, and
    3. Yates JR III.
    (2008) Mass spectrometry for proteomics. Curr Opin Chem Biol 12:483–490.
    OpenUrlCrossRefPubMed
  10. ↵
    1. Kimoto E,
    2. Yoshida K,
    3. Balogh LM,
    4. Bi YA,
    5. Maeda K,
    6. El-Kattan A,
    7. Sugiyama Y, and
    8. Lai Y
    (2012) Characterization of organic anion transporting polypeptide (OATP) expression and its functional contribution to the uptake of substrates in human hepatocytes. Mol Pharm 9:3535–3542.
    OpenUrlCrossRef
  11. ↵
    1. Lange V,
    2. Picotti P,
    3. Domon B, and
    4. Aebersold R
    (2008) Selected reaction monitoring for quantitative proteomics: a tutorial. Mol Syst Biol 4:222.
    OpenUrlAbstract/FREE Full Text
  12. ↵
    1. Peng KW,
    2. Bacon J,
    3. Zheng M,
    4. Guo Y, and
    5. Wang MZ
    (2015) Ethnic variability in the expression of hepatic drug transporters: absolute quantification by an optimized targeted quantitative proteomic approach. Drug Metab Dispos 43:1045–1055.
    OpenUrlAbstract/FREE Full Text
  13. ↵
    1. Peterson AC,
    2. Russell JD,
    3. Bailey DJ,
    4. Westphall MS, and
    5. Coon JJ
    (2012) Parallel reaction monitoring for high resolution and high mass accuracy quantitative, targeted proteomics. Mol Cell Proteomics 11:1475–1488.
    OpenUrlAbstract/FREE Full Text
  14. ↵
    1. Prasad B and
    2. Unadkat JD
    (2014) Optimized approaches for quantification of drug transporters in tissues and cells by MRM proteomics. AAPS J 16:634–648.
    OpenUrlCrossRefPubMed
  15. ↵
    1. Qiu X,
    2. Bi YA,
    3. Balogh LM, and
    4. Lai Y
    (2013) Absolute measurement of species differences in sodium taurocholate cotransporting polypeptide (NTCP/Ntcp) and its modulation in cultured hepatocytes. J Pharm Sci 102:3252–3263.
    OpenUrlCrossRefPubMed
  16. ↵
    1. Sakamoto A,
    2. Matsumaru T,
    3. Ishiguro N,
    4. Schaefer O,
    5. Ohtsuki S,
    6. Inoue T,
    7. Kawakami H, and
    8. Terasaki T
    (2011) Reliability and robustness of simultaneous absolute quantification of drug transporters, cytochrome P450 enzymes, and Udp-glucuronosyltransferases in human liver tissue by multiplexed MRM/selected reaction monitoring mode tandem mass spectrometry with nano-liquid chromatography. J Pharm Sci 100:4037–4043.
    OpenUrlCrossRefPubMed
  17. ↵
    1. Tabb DL,
    2. Vega-Montoto L,
    3. Rudnick PA,
    4. Variyath AM,
    5. Ham AJ,
    6. Bunk DM,
    7. Kilpatrick LE,
    8. Billheimer DD,
    9. Blackman RK,
    10. Cardasis HL, et al.
    (2010) Repeatability and reproducibility in proteomic identifications by liquid chromatography-tandem mass spectrometry. J Proteome Res 9:761–776.
    OpenUrlCrossRefPubMed
  18. ↵
    1. Thompson A,
    2. Schäfer J,
    3. Kuhn K,
    4. Kienle S,
    5. Schwarz J,
    6. Schmidt G,
    7. Neumann T,
    8. Johnstone R,
    9. Mohammed AK, and
    10. Hamon C
    (2003) Tandem mass tags: a novel quantification strategy for comparative analysis of complex protein mixtures by MS/MS [published corrections appear in Anal Chem (2003) 75:4942; Anal Chem (2006) 78:4235]. Anal Chem 75:1895–1904.
    OpenUrlCrossRefPubMed
  19. ↵
    1. Ting L,
    2. Rad R,
    3. Gygi SP, and
    4. Haas W
    (2011) MS3 eliminates ratio distortion in isobaric multiplexed quantitative proteomics. Nat Methods 8:937–940.
    OpenUrlCrossRefPubMed
  20. ↵
    1. Vildhede A,
    2. Mateus A,
    3. Khan EK,
    4. Lai Y,
    5. Karlgren M,
    6. Artursson P, and
    7. Kjellsson MC
    (2016) Mechanistic modeling of pitavastatin disposition in sandwich-cultured human hepatocytes: a proteomics-informed bottom-up approach. Drug Metab Dispos 44:505–516.
    OpenUrlAbstract/FREE Full Text
  21. ↵
    1. Walther TC and
    2. Mann M
    (2010) Mass spectrometry-based proteomics in cell biology. J Cell Biol 190:491–500.
    OpenUrlAbstract/FREE Full Text
  22. ↵
    1. Wang L,
    2. Prasad B,
    3. Salphati L,
    4. Chu X,
    5. Gupta A,
    6. Hop CE,
    7. Evers R, and
    8. Unadkat JD
    (2015) Interspecies variability in expression of hepatobiliary transporters across human, dog, monkey, and rat as determined by quantitative proteomics. Drug Metab Dispos 43:367–374.
    OpenUrlAbstract/FREE Full Text
  23. ↵
    1. Wegler C,
    2. Gaugaz FZ,
    3. Andersson TB,
    4. Wiśniewski JR,
    5. Busch D,
    6. Gröer C,
    7. Oswald S,
    8. Norén A,
    9. Weiss F,
    10. Hammer HS, et al.
    (2017) Variability in mass spectrometry-based quantification of clinically relevant drug transporters and drug metabolizing enzymes. Mol Pharm 14:3142–3151.
    OpenUrl
  24. ↵
    1. Wiśniewski JR
    (2017) Label-free and standard-free absolute quantitative proteomics using the “Total Protein” and “Proteomic Ruler” approaches. Methods Enzymol 585:49–60.
    OpenUrl
  25. ↵
    1. Wiśniewski JR,
    2. Ostasiewicz P,
    3. Duś K,
    4. Zielińska DF,
    5. Gnad F, and
    6. Mann M
    (2012) Extensive quantitative remodeling of the proteome between normal colon tissue and adenocarcinoma. Mol Syst Biol 8:611.
    OpenUrlAbstract/FREE Full Text
  26. ↵
    1. Wiśniewski JR and
    2. Rakus D
    (2014) Multi-enzyme digestion FASP and the ‘Total Protein Approach’-based absolute quantification of the Escherichia coli proteome. J Proteomics 109:322–331.
    OpenUrl
  27. ↵
    1. Wiśniewski JR,
    2. Wegler C, and
    3. Artursson P
    (2016) Subcellular fractionation of human liver reveals limits in global proteomic quantification from isolated fractions. Anal Biochem 509:82–88.
    OpenUrl
  28. ↵
    1. Zhang Y,
    2. Fonslow BR,
    3. Shan B,
    4. Baek MC, and
    5. Yates JR III.
    (2013) Protein analysis by shotgun/bottom-up proteomics. Chem Rev 113:2343–2394.
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

Drug Metabolism and Disposition: 46 (5)
Drug Metabolism and Disposition
Vol. 46, Issue 5
1 May 2018
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Editorial Board (PDF)
  • Front Matter (PDF)
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for sharing this Drug Metabolism & Disposition article.

NOTE: We request your email address only to inform the recipient that it was you who recommended this article, and that it is not junk mail. We do not retain these email addresses.

Enter multiple addresses on separate lines or separate them with commas.
Comparison of Proteomic Quantification Approaches for Hepatic Drug Transporters: Multiplexed Global Quantitation Correlates with Targeted Proteomic Quantitation
(Your Name) has forwarded a page to you from Drug Metabolism & Disposition
(Your Name) thought you would be interested in this article in Drug Metabolism & Disposition.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Rapid CommunicationSpecial Section on Transporters in Drug Disposition and Pharmacokinetic Prediction—Short Communication

Targeted versus Global Proteomic Quantification of Transporters

Anna Vildhede, Chuong Nguyen, Brian K. Erickson, Ryan C. Kunz, Richard Jones, Emi Kimoto, Francis Bourbonais, A. David Rodrigues and Manthena V.S. Varma
Drug Metabolism and Disposition May 1, 2018, 46 (5) 692-696; DOI: https://doi.org/10.1124/dmd.117.079285

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Rapid CommunicationSpecial Section on Transporters in Drug Disposition and Pharmacokinetic Prediction—Short Communication

Targeted versus Global Proteomic Quantification of Transporters

Anna Vildhede, Chuong Nguyen, Brian K. Erickson, Ryan C. Kunz, Richard Jones, Emi Kimoto, Francis Bourbonais, A. David Rodrigues and Manthena V.S. Varma
Drug Metabolism and Disposition May 1, 2018, 46 (5) 692-696; DOI: https://doi.org/10.1124/dmd.117.079285
Reddit logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Materials and Methods
    • Results and Discussion
    • Authorship Contributions
    • Footnotes
    • Abbreviations
    • References
  • Figures & Data
  • Info & Metrics
  • eLetters
  • PDF + SI
  • PDF

Related Articles

Cited By...

Similar Articles

Advertisement
  • Home
  • Alerts
Facebook   Twitter   LinkedIn   RSS

Navigate

  • Current Issue
  • Fast Forward by date
  • Fast Forward by section
  • Latest Articles
  • Archive
  • Search for Articles
  • Feedback
  • ASPET

More Information

  • About DMD
  • Editorial Board
  • Instructions to Authors
  • Submit a Manuscript
  • Customized Alerts
  • RSS Feeds
  • Subscriptions
  • Permissions
  • Terms & Conditions of Use

ASPET's Other Journals

  • Journal of Pharmacology and Experimental Therapeutics
  • Molecular Pharmacology
  • Pharmacological Reviews
  • Pharmacology Research & Perspectives
ISSN 1521-009X (Online)

Copyright © 2023 by the American Society for Pharmacology and Experimental Therapeutics