TABLE 3

Detailed description of analytical methods


Sample cleanup

    Cartridge C18; 100 mg/l ml; International Sorbent Technology, Great Britain
    Buffer A Aqueous solution of 150 mM ammonium acetate, pH 4.5 (acetic acid)
    Buffer B Aqueous solution of 15 mM ammonium acetate, pH 4.5 (acetic acid)
Liquid chromatography
    Eluent A 15 mM ammonium acetate, water/acetonitrile (9:1), pH 4.2 (formic acid)
    Eluent B 15 mM ammonium acetate, water/acetonitrile (1:9), pH 4.2 (formic acid)
    Flow 0.5 ml/min, post-column split 1:10
    Gradient program B: linear increase from 25 to 40% in 11 min, 90% for 2 min, 3 min equilibration
    Column Purospher RP-18; 125 × 3 mm, particle size 5 μm, end-capped
    Injection 5 μl
Mass spectrometry
    Ionspray voltage 5500 V, positive ion mode electrospray
    Orifice voltage 20 V
    Nebulizing gas Purified air, 0.82 l/min, Atlas Copco, Belgium
    Curtain gas Nitrogen, 0.95 l/min, Generator system 75-72, Whatman (Clifton, NJ)
    Collision gas Nitrogen, generator system 75-72, Whatman
    Turbo gas
Nitrogen, 6 l/min, 350°C, Generator system 75-72, Whatman