TABLE 2

Accurate mass results for the CID (LC-QTOF) and EI (GC-TOF) fragments detected in methyltestosterone metabolites

For proposed structures see Figs. 4 and 8.

AnalyteLC-QTOF
GC-TOF
Experimental ResultIonErrorExperimental ResultIonError
m/z mDa m/z mDa
A1/A4303.2325C20H31O20.3446.3047C26H46O2Si21.1
285.2205C20H29O1.3356.2580C23H36OSi1.3
267.2127C20H271.4341.2320C22H33OSi1.9
245.1913C17H25O0.8301.1989C19H29OSi0.1
229.1597C16H21O0.5247.1527C15H23OSi0.9
227.1781C17H231.9198.1429C11H22OSi1.1
211.1495C16H190.8193.1047C11H17OSi0.2
109.0648C7H9O0.5143.0906C7H15OSi1.4
97.0644C6H9O0.9
A5301.2168C20H29O20.0444.2877C26H44O2Si20.3
283.2061C20H27O0.1354.2391C23H34OSi1.2
268.1833C19H24O0.6339.2169C22H31OSi0.7
265.1940C20H251.6299.1847C19H27OSi1.6
239.1814C18H231.4245.1346C15H21OSi1.6
225.1643C17H210.4197.1351C11H21OSi1.1
210.1416C16H180.7193.1050C11H17OSi0.1
195.1175C15H150.1143.0890C7H15OSi0.2
183.1167C14H150.7
169.1007C13H131.0