TABLE 2

Primer sequence used for real-time RT-PCR quantification and for calibrator preparation


Isoform

F Primer

R Primer

Amplicon Size
bp
For calibrator preparation
    1A1 5′-AATAAAAAAGGACTTGCTATGCT-3′ 562*
    1A3 5′-TGTTGAACAATATGTTTTGGTCTA-3′ 562*
    1A4 5′-GAACAATGTATCTTTGCCC-3′ 558*
    1A5 5′-TATGAACAATATGTCTTGATCATACA-3′ 561*
    1A6 5′-CATGATTGTTATTGGCTGTAC-3′ 558*
    1A7 5′-GCGAAGTGCATTTTCCTATTAAC-3′ 591*
    1A8 5′-GAAAGCACAAGTACAAGTTTG-3′ 603*
    1A9 5′-TGGAAAGCACAAGTCGAAGTATATA-3′ 605*
    1A10 5′-GAAAGCACAGGCACAAGTATA-3′ 603*
    Common primer 5′-ATTCCATGTTTCCAGAAGCA-3′
For quantification
    1A1 5′-AATAAAAAAGGCTCTGCTATGCT-3′ 5′-ACATCAAACTGCTTTCTGC-3′ 96
    1A3 5′-TGTTGAACAATAGTCTTTGGTCTA-3′ 5′-ACCACATCAAGGAAGTAGCA-3′ 100
    1A4 5′-GAACAATGTATCTTGGCCC-3′ 5′-ACCACATCAAGGAAGTAGCA-3′ 96
    1A5 5′-TATGAACAATATTCTTTGATCATACA-3′ 5′-ACCACATCAAGGAAGTAGCA-3′ 99
    1A6 5′-CATGATTGTTATGGCCTGTAC-3′ 5′-TCTGTGAAAGAGCATCAAACT-3′ 105
    1A7 5′-GCGAAGTGCATTTCTCTATTAAC-3′ 5′-GGGAGGGAAAATATTTGGC-3′ 186
    1A8 5′-GAAAGCACAAGACGAAGTTTG-3′ 5′-GGGAGGGAAAATATTTGGC-3′ 198
    1A9 5′-TGGAAAGCACAGTACGAAGTATATA-3′ 5′-GGGAGGGAAAATATTTGGC-3′ 200
    1A10 5′-GAAAGCACAGGACAAAGTATA-3′ 5′-GGGAGGGAAAATATTTAGCAAC-3′ 198
For quantification and calibrator preparation
    2B4 5′-TCTTTCGATCCAACAGCC-3′ 5′-CATCTCTTAACCGCTGCTTGATA-3′ 104
    2B7 5′-GGAGAATTTCTCATGCAACAGA-3′ 5′-CAGAACTTTCTATTATGTCACCAAATATTG-3′ 123
    2B10 5′-ATTTGAGAATTCATCATGCAAT-3′ 5′-ATGTCATTAATTCCCACAG-3′ 111
    2B11 5′-TCAGACATTCAAAAGATAGC-3′ 5′-ATCTTTACAGAATTTCTAAATATGTCATAT-3′ 96
    2B15 5′-CTTCTGAAAATCTCGATAGATGGAT-3′ 5′-CATCTTTACAGACTTGTTACTGTAGTCAT-3′ 124
    2B17 5′-TTTATGAAAAGTTCGATAGATGGAC-3′ 5′-CATCTTCACAGACTTTATATTATAGTCAG-3′ 124
For calibrator preparation
    GAPDH 5′-ATGGGGAAGTGAAGGTCG-3′ 5′-TTACTCCTTGAGGCCATGT-3′ 1008
For quantification
    GAPDH
5′-TCCACTGGCTCTTCACC-3′
5′-GGCAGAGATATGACCCTTTT-3′
78
  • F, forward; R, reverse.

  • * Amplicon Size with common R primer.