TABLE 2

Observed and predicted biliary excretion of 50 BMS compounds

r = 0.94 between observation and prediction. The mean of the differences is 0, whereas the mean of the absolute differences is 7.8% of the dose.

CompoundObservationPredictionDifferenceAbsolute Difference
% dose% dose
I3.0−6.4−9.49.4
II1.3−6.9−8.28.2
III1.513.612.112.1
IV67.864.3−3.53.5
V0.75.14.44.4
VI80.079.4−0.60.6
VII8.67.4−1.21.2
VIII4.05.31.31.2
IX83.070.5−12.512.5
X5.29.64.44.4
XI0.55.65.15.5
XII0.74.33.63.6
XIII11.51.2−10.310.3
XIV1.07.26.26.2
XV83.982.5−1.41.4
XVI80.278.0−2.22.2
XVII32.422.3−10.110.1
XVIII77.090.613.613.6
XIX81.877.14.74.7
XX41.421.3−20.120.1
XXI60.085.625.625.6
XXII11.915.53.63.6
XXIII29.719.1−10.610.6
XXIV2.721.118.418.4
XXV63.234.1−29.129.1
XXVI33.027.5−5.55.5
XXVII43.928.1−15.815.8
XXVIII0.11.91.81.8
XXIX9.426.417.017.0
XXX0.51.71.21.2
XXXI10.424.013.613.6
XXXII19.77.8−11.911.9
XXXIII27.422.3−5.15.1
XXXIV6.413.77.37.3
XXXV30.327.4−2.92.9
XXXVI1.94.42.52.5
XXXVII3.713.39.69.6
XXXVIII92.182.8−9.39.3
XXXIX0.1−2.5−2.62.6
XL47.034.2−12.812.8
XLI4.49.14.74.7
XLII0.210.510.310.3
XLIII8.010.22.22.2
XLIV25.525.2−0.30.3
XLV21.721.4−0.30.3
XLVI2.04.42.42.4
XLVII20.731.410.710.7
XLVIII10095.0−5.05.0
IL29.539.29.79.7
L0.14.24.14.1